ReaLoad.com · NEC Article 702 & NFPA 54 Field Card (Page 1 of 2)
Winter & Hurricane Generator Hookup Checklist
My Generator: _______________________
Neutral Status: [ ] Floating [ ] Bonded
1. Mandatory 20-Foot Carbon Monoxide Setback Rule
- Never run any combustion generator indoors, inside an attached garage, breezeway, porch, or crawlspace, even with bay doors open.
- Position the unit at least 20 feet away from windows, doors, dryer vents, and HVAC fresh-air intakes with exhaust pointed away from the home.
- Keep battery-backed digital carbon monoxide alarms active on every floor and near bedrooms before starting the engine.
2. Neutral Bonding Check (NEC Article 250.20)
- Home Panel Interlock / 2-Pole Transfer Switch: Your main home service panel bonds Neutral to Ground. Your generator MUST be Floating Neutral to avoid parallel ground-loop currents and GFCI trips.
- Standalone Extension Cords / RV Surge Guard EMS: Insert a 120V NEMA 5-15P Neutral-Ground Bonding Plug into a spare receptacle when using standalone cords or RV EMS protection.
3. Exact 30A / 50A Breaker Interlock Startup & Grid-Restore Sequence
A. Blackout Startup Sequence (Grid Down)
- Switch the 200A Utility Main Breaker to OFF.
- Switch ALL individual branch circuit breakers to OFF (prevents cold-load surge stall).
- Slide mechanical interlock plate upward to unblock the 30A/50A Generator Backfeed Breaker (leave OFF).
- Plug 4-prong locking cord (14-50P or L14-30P) into exterior NEMA 3R inlet box and generator.
- Start generator outdoors and warm up for 2 full minutes with ECO mode OFF.
- Flip Generator Backfeed Breaker ON, then enable circuits one at a time (Well/Heat -> Fridge -> Lights).
B. Grid Restoration Sequence (Utility Back On)
- Flip the 30A/50A Generator Backfeed Breaker to OFF first.
- Slide mechanical interlock plate down to lock out the generator breaker.
- Flip the 200A Utility Main Breaker to ON and restore branch circuits.
- Let generator run unloaded outdoors for 3 minutes to cool inverter electronics and stator.
- If running gasoline, turn fuel valve to FUEL OFF (or drain bowl) so carburetor runs dry before storage.
- Shut down engine, unplug inlet cord, coil dry indoors, and latch exterior inlet cover.
ReaLoad.com · Winter Fuel, Breaker Load Map & Maintenance Log (Page 2 of 2)
NEC 702 / NFPA 54
4. Winter Propane Tank Freeze-Up Table (-20°F to +40°F) & Natural Gas Hose Rules
Open Interactive Propane Freeze Simulator ->| Ambient Temp | 20-lb Grill Tank (50% Full) | 40-lb RV Cylinder | 100-lb Vertical Tank | Field Action Required |
|---|---|---|---|---|
| +40°F (4°C) | 46,000 BTU/hr (~3.8 kW max) | 69,000 BTU/hr (~5.5 kW max) | 115,000 BTU/hr (~9.0 kW max) | 20-lb tank handles light 3.5kW loads |
| +20°F (-7°C) | 31,000 BTU/hr (~2.4 kW max) | 47,000 BTU/hr (~3.8 kW max) | 78,000 BTU/hr (~6.2 kW max) | 20-lb tank frosts over above 2,400W |
| 0°F (-18°C) | 18,000 BTU/hr (~1.4 kW max) | 27,000 BTU/hr (~2.1 kW max) | 48,000 BTU/hr (~3.8 kW max) | Use dual-tank manifold or 100-lb cylinder |
| -20°F (-29°C) | 8,500 BTU/hr (Stalls 5kW+ units) | 13,000 BTU/hr (~1.0 kW max) | 24,000 BTU/hr (~1.9 kW max) | Switch to utility Natural Gas or gasoline |
Natural Gas Quick-Connect Check (NFPA 54): Use a full-port 3/4-inch ID CSA quick-connect hose for any tri-fuel generator rated 8,000W or higher on runs over 15 feet. A 1/2-inch BBQ hose restricts gas flow above 95,000 BTU/hr and drops inlet pressure below 5.0 inches Water Column under compressor surges.
5. Breaker Priority Load Map & Pre-Storm Maintenance Log
| Breaker # | Circuit Name (Kitchen, Furnace, Well, Sump, Internet) | Running W | Surge W | Priority (1-3) |
|---|---|---|---|---|
| 1. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 | |
| 2. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 | |
| 3. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 | |
| 4. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 | |
| 5. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 | |
| 6. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 | |
| 7. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 | |
| 8. _____ | _______ W | _______ W | [ ] 1 [ ] 2 [ ] 3 |
| Pre-Storm Maintenance Item | Target Check | Log Entry A | Log Entry B |
|---|---|---|---|
| Engine Oil Change & Filter | Record SAE viscosity & fill qt | Date: __________ | Hours: __________ |
| Spark Plug Gap & Replacement | OEM or NGK equivalent gap | Plug: __________ | Gap: __________ |
| Fuel Bowl Drain / Stabilizer | Run carb dry after gas storm use | Status: __________ | Date: __________ |
| Electric Starter Battery & CO Alarm | Trickle-charge 12V battery & test alarms | Voltage: __________ | Tested: __________ |
| Utility Outage & Licensed Electrician | Emergency disconnect & service numbers | Utility: __________ | Tech: __________ |