Champion 201438 vs. Genmax GM11000iET
Comparing the Champion 201438 and Genmax GM11000iET weighs surge headroom against transfer switch readiness. The Champion 201438 leads continuous output at 10,000 running watts (12,500W peak, Bonded Neutral), whereas the Genmax GM11000iET delivers 8,500 running watts (11,000W peak, Floating Neutral).
Head-to-Head Verdict: 201438 vs GM11000iET
Champion 201438 leads by 1,500W running and 1,500W peak (10,000W vs 8,500W on gasoline). A compressor soft-starter trims HVAC inrush 65%.
At 50% load over 72 hours, 201438 burns ~69.1 gal ($249) vs ~63.4 gal ($228) on GM11000iET, a 5.7-gallon ($21) fuel delta.
GM11000iET runs 10 dBA quieter at 23 ft (76 vs 66 dBA @ 50% load). For transport, 201438 weighs 16 lbs less (231 vs 247 lbs dry).
201438 (Bonded Neutral) provides NEMA 14-50R, NEMA L14-30R, NEMA 5-20R GFCI; GM11000iET (Floating Neutral) provides NEMA 14-50R, NEMA L14-30R, NEMA 5-20R Duplex. Match floating neutral for 3-pole home interlock panels per NEC 250.
| Technical Specification | ||
|---|---|---|
Price Cost & Value | Price: $1,335Best | Price: $2,199 |
Supported Fuels Power Output | Gasoline / Propane / Natural Gas | Gasoline / Propane / Natural Gas |
Running Watts Power Output | 10,000 WBest | 8,500 W |
Peak Starting Surge Power Output | 12,500 WBest | 11,000 W |
240V Output Amps Power Output | 41.7 ABest | 35.4 A |
Sine Wave Purity Power Quality | <19.9% THD (Pure Sine) | <2.5% THD (Pure Sine)Best |
Fuel Burn (25%) Fuel Consumption | 0.62 GPH | 0.49 GPHBest |
Fuel Burn (50%) Fuel Consumption | 0.96 GPH | 0.88 GPHBest |
Runtime (25% Load) Fuel Consumption | 12.4 Hours | 14 HoursBest |
Fuel Tank Capacity Fuel Consumption | 7.7 GallonsBest | 6.9 Gallons |
14-50R 50A Outlet Outlets & Receptacles | 1x NEMA 14-50R (50A)Best | 1x NEMA 14-50R (50A)Best |
L14-30R 30A Outlet Outlets & Receptacles | 1x NEMA L14-30R (30A)Best | 1x NEMA L14-30R (30A)Best |
TT-30R RV Outlet Outlets & Receptacles | NoneBest | NoneBest |
5-20R Duplex Outlets Outlets & Receptacles | 4x NEMA 5-20R DuplexBest | 2x NEMA 5-20R Duplex |
Engine Start Method Starting & Safety | Electric Push-Button & Recoil Pull | Wireless Remote, Electric Key & Recoil |
Carbon Monoxide Sensor Starting & Safety | CO Watchdog / Shield Sensor (ANSI/PGMA G300) | CO Watchdog / Shield Sensor (ANSI/PGMA G300) |
Noise Level (23ft) Acoustics & Physical | 74 dBA | 62 dBABest |
Chassis Dimensions Acoustics & Physical | 29" L × 28.5" W × 25.8" H | 30.9" L × 22.6" W × 29.3" H |
Dry Weight Acoustics & Physical | 231 lbsBest | 247 lbs |
Neutral Bonding NEC 2026 Hookup | Bonded Neutral (Unbonding Required for Home ATS) | Floating Neutral (Ready for Home Interlock) |
Shop & Check Live Price Authorized partner links |