Skip to main content
ReaLoad Engineering Benchmark

Champion 201438 vs. Genmax GM12500iET

ReaLoad Engineering Desk:
Quick Summary

Comparing the Genmax GM12500iET and Champion 201438 weighs surge headroom against transfer switch readiness. The Genmax GM12500iET leads continuous output at 10,500 running watts (12,500W peak, Bonded Neutral), whereas the Champion 201438 delivers 10,000 running watts (12,500W peak, Bonded Neutral).

Head-to-Head Verdict: 201438 vs GM12500iET

Wattage & LRA Surge Delta

Genmax GM12500iET leads by 500W running and 0W peak (10,000W vs 10,500W on gasoline). A compressor soft-starter trims HVAC inrush 65%.

72-Hour Fuel Cost Delta

At 50% load over 72 hours, 201438 burns ~69.1 gal ($249) vs ~68.4 gal ($246) on GM12500iET, a 0.7-gallon ($3) fuel delta.

Noise & Weight Delta

GM12500iET runs 9 dBA quieter at 23 ft (76 vs 67 dBA @ 50% load). For transport, 201438 weighs 16 lbs less (231 vs 247 lbs dry).

Outlets & Neutral Bonding

201438 (Bonded Neutral) provides NEMA 14-50R, NEMA L14-30R, NEMA 5-20R GFCI; GM12500iET (Bonded Neutral) provides NEMA 14-50R, NEMA L5-30R, NEMA 5-20R Duplex. Match floating neutral for 3-pole home interlock panels per NEC 250.

Natural Gas Leader
Genmax GM12500iET
8,500 W running on NG (+500 W lead)
Acoustic Winner
Genmax GM12500iET
62 dBA at 23ft (-12 dBA quieter)
Easiest Home Hookup
Champion 201438
Bonded Neutral (Home Interlock Ready)
Best $/Running Watt
Champion 201438
$0.13/W ($1,335)
Compared ModelsChampion 201438Genmax GM12500iET
Technical Specification
Champion 201438 12,500W Starting / 10,000W Running Tri-Fuel Portable Generator
Genmax GM12500iET 12,500W Peak / 10,500W Running Tri-Fuel Enclosed Inverter
Price
Cost & Value
Price: $1,335Best
Price: $1,899
Supported Fuels
Power Output
Gasoline / Propane / Natural Gas
Gasoline / Propane / Natural Gas
Running Watts
Power Output
10,000 W
10,500 WBest
Peak Starting Surge
Power Output
12,500 WBest
12,500 WBest
240V Output Amps
Power Output
41.7 A
43.8 ABest
Sine Wave Purity
Power Quality
<19.9% THD (Pure Sine)
<2.5% THD (Pure Sine)Best
Fuel Burn (25%)
Fuel Consumption
0.62 GPH
0.56 GPHBest
Fuel Burn (50%)
Fuel Consumption
0.96 GPH
0.95 GPHBest
Runtime (25% Load)
Fuel Consumption
12.4 HoursBest
12.3 Hours
Fuel Tank Capacity
Fuel Consumption
7.7 GallonsBest
6.9 Gallons
14-50R 50A Outlet
Outlets & Receptacles
1x NEMA 14-50R (50A)Best
1x NEMA 14-50R (50A)Best
L14-30R 30A Outlet
Outlets & Receptacles
1x NEMA L14-30R (30A)Best
None
TT-30R RV Outlet
Outlets & Receptacles
NoneBest
NoneBest
5-20R Duplex Outlets
Outlets & Receptacles
4x NEMA 5-20R DuplexBest
2x NEMA 5-20R Duplex
Engine Start Method
Starting & Safety
Electric Push-Button & Recoil Pull
Wireless Remote, Electric Key & Recoil
Carbon Monoxide Sensor
Starting & Safety
CO Watchdog / Shield Sensor (ANSI/PGMA G300)
CO Watchdog / Shield Sensor (ANSI/PGMA G300)
Noise Level (23ft)
Acoustics & Physical
74 dBA
62 dBABest
Chassis Dimensions
Acoustics & Physical
29" L × 28.5" W × 25.8" H
30.9" L × 22.9" W × 29.3" H
Dry Weight
Acoustics & Physical
231 lbsBest
247 lbs
Neutral Bonding
NEC 2026 Hookup
Bonded Neutral (Unbonding Required for Home ATS)
Bonded Neutral (Unbonding Required for Home ATS)
Shop & Check Live Price
Authorized partner links