Champion 201438 vs. Westinghouse iGen8200TFc
Comparing the Champion 201438 and Westinghouse iGen8200TFc weighs surge headroom against transfer switch readiness. The Champion 201438 leads continuous output at 10,000 running watts (12,500W peak, Bonded Neutral), whereas the Westinghouse iGen8200TFc delivers 6,600 running watts (8,200W peak, Bonded Neutral).
Head-to-Head Verdict: 201438 vs iGen8200TFc
Champion 201438 leads by 3,400W running and 4,300W peak (10,000W vs 6,600W on gasoline). A compressor soft-starter trims HVAC inrush 65%.
At 50% load over 72 hours, 201438 burns ~69.1 gal ($249) vs ~28.8 gal ($104) on iGen8200TFc, a 40.3-gallon ($145) fuel delta.
iGen8200TFc runs 12 dBA quieter at 23 ft (76 vs 64 dBA @ 50% load). For transport, iGen8200TFc weighs 96.5 lbs less (231 vs 134.5 lbs dry).
201438 (Bonded Neutral) provides NEMA 14-50R, NEMA L14-30R, NEMA 5-20R GFCI; iGen8200TFc (Bonded Neutral) provides NEMA 14-50R, NEMA TT-30R, NEMA 5-20R GFCI. Match floating neutral for 3-pole home interlock panels per NEC 250.
| Technical Specification | ||
|---|---|---|
Price Cost & Value | Price: $1,335 | Price: $1,249Best |
Supported Fuels Power Output | Gasoline / Propane / Natural Gas | Gasoline / Propane / Natural Gas |
Running Watts Power Output | 10,000 WBest | 6,600 W |
Peak Starting Surge Power Output | 12,500 WBest | 8,200 W |
240V Output Amps Power Output | 41.7 ABest | 27.5 A |
Sine Wave Purity Power Quality | <19.9% THD (Pure Sine) | <2.3% THD (Pure Sine)Best |
Fuel Burn (25%) Fuel Consumption | 0.62 GPH | 0.23 GPHBest |
Fuel Burn (50%) Fuel Consumption | 0.96 GPH | 0.40 GPHBest |
Runtime (25% Load) Fuel Consumption | 12.4 Hours | 17 HoursBest |
Fuel Tank Capacity Fuel Consumption | 7.7 GallonsBest | 3.96 Gallons |
14-50R 50A Outlet Outlets & Receptacles | 1x NEMA 14-50R (50A)Best | 1x NEMA 14-50R (50A)Best |
L14-30R 30A Outlet Outlets & Receptacles | 1x NEMA L14-30R (30A)Best | None |
TT-30R RV Outlet Outlets & Receptacles | None | 1x NEMA TT-30R (RV)Best |
5-20R Duplex Outlets Outlets & Receptacles | 4x NEMA 5-20R DuplexBest | 1x NEMA 5-20R Duplex |
Engine Start Method Starting & Safety | Electric Push-Button & Recoil Pull | Wireless Remote, Electric Key & Recoil |
Carbon Monoxide Sensor Starting & Safety | CO Watchdog / Shield Sensor (ANSI/PGMA G300) | CO Watchdog / Shield Sensor (ANSI/PGMA G300) |
Noise Level (23ft) Acoustics & Physical | 74 dBA | 60 dBABest |
Chassis Dimensions Acoustics & Physical | 29" L × 28.5" W × 25.8" H | 27" L × 20.9" W × 21.7" H |
Dry Weight Acoustics & Physical | 231 lbs | 134.5 lbsBest |
Neutral Bonding NEC 2026 Hookup | Bonded Neutral (Unbonding Required for Home ATS) | Bonded Neutral (Unbonding Required for Home ATS) |
Shop & Check Live Price Authorized partner links |