Skip to main content
ReaLoad Engineering Benchmark

GENMAX GM9000iED vs. Westinghouse WGen9500TFc

ReaLoad Engineering Desk:
Quick Summary

Comparing the Westinghouse WGen9500TFc and GENMAX GM9000iED weighs surge headroom against transfer switch readiness. The Westinghouse WGen9500TFc leads continuous output at 9,500 running watts (12,500W peak, Bonded Neutral), whereas the GENMAX GM9000iED delivers 7,600 running watts (9,000W peak, Bonded Neutral).

Head-to-Head Verdict: GM9000iED vs WGen9500TFc

Wattage & LRA Surge Delta

Westinghouse WGen9500TFc leads by 1,900W running and 3,500W peak (7,600W vs 9,500W on gasoline). A compressor soft-starter trims HVAC inrush 65%.

72-Hour Fuel Cost Delta

At 50% load over 72 hours, GM9000iED burns ~53.3 gal ($192) vs ~59.8 gal ($215) on WGen9500TFc, a 6.5-gallon ($23) fuel delta.

Noise & Weight Delta

GM9000iED runs 11.5 dBA quieter at 23 ft (64.5 vs 76 dBA @ 50% load). For transport, WGen9500TFc weighs 40.2 lbs less (243.6 vs 203.4 lbs dry).

Outlets & Neutral Bonding

GM9000iED (Bonded Neutral) provides NEMA 14-50R, NEMA L14-30R, NEMA 5-20R GFCI; WGen9500TFc (Bonded Neutral) provides NEMA 14-50R, NEMA L14-30R, NEMA 5-20R GFCI. Match floating neutral for 3-pole home interlock panels per NEC 250.

Natural Gas Leader
Westinghouse WGen9500TFc
7,500 W running on NG (+7500 W lead)
Acoustic Winner
GENMAX GM9000iED
62 dBA at 23ft (-12 dBA quieter)
Easiest Home Hookup
GENMAX GM9000iED
Bonded Neutral (Home Interlock Ready)
Best $/Running Watt
Westinghouse WGen9500TFc
$0.12/W ($1,149)
Compared ModelsGENMAX GM9000iEDWestinghouse WGen9500TFc
Technical Specification
GENMAX GM9000iED 9,000W Peak / 7,600W Running Enclosed Dual-Fuel Inverter
Westinghouse WGen9500TFc 12,500W Peak / 9,500W Running Tri-Fuel Portable Generator
Price
Cost & Value
Price: $1,799
Price: $1,149Best
Supported Fuels
Power Output
Gasoline / Propane
Gasoline / Propane / Natural Gas
Running Watts
Power Output
7,600 W
9,500 WBest
Peak Starting Surge
Power Output
9,000 W
12,500 WBest
240V Output Amps
Power Output
31.7 A
39.6 ABest
Sine Wave Purity
Power Quality
<2.2% THD (Pure Sine)Best
<22.9% THD (Pure Sine)
Fuel Burn (25%)
Fuel Consumption
0.49 GPHBest
0.55 GPH
Fuel Burn (50%)
Fuel Consumption
0.74 GPHBest
0.83 GPH
Runtime (25% Load)
Fuel Consumption
14 HoursBest
12 Hours
Fuel Tank Capacity
Fuel Consumption
6.9 GallonsBest
6.6 Gallons
14-50R 50A Outlet
Outlets & Receptacles
1x NEMA 14-50R (50A)Best
1x NEMA 14-50R (50A)Best
L14-30R 30A Outlet
Outlets & Receptacles
1x NEMA L14-30R (30A)Best
1x NEMA L14-30R (30A)Best
TT-30R RV Outlet
Outlets & Receptacles
NoneBest
NoneBest
5-20R Duplex Outlets
Outlets & Receptacles
2x NEMA 5-20R Duplex
4x NEMA 5-20R DuplexBest
Engine Start Method
Starting & Safety
Wireless Remote, Electric Key & Recoil
Wireless Remote, Electric Key & Recoil
Carbon Monoxide Sensor
Starting & Safety
CO Watchdog / Shield Sensor (ANSI/PGMA G300)
CO Watchdog / Shield Sensor (ANSI/PGMA G300)
Noise Level (23ft)
Acoustics & Physical
62 dBABest
74 dBA
Chassis Dimensions
Acoustics & Physical
30.9" L × 22.6" W × 29.3" H
27.2" L × 26.1" W × 26.5" H
Dry Weight
Acoustics & Physical
243.6 lbs
203.4 lbsBest
Neutral Bonding
NEC 2026 Hookup
Bonded Neutral (Unbonding Required for Home ATS)
Bonded Neutral (Unbonding Required for Home ATS)
Shop & Check Live Price
Authorized partner links