Predator 2000W Super Quiet Inverter Generator
Who It's Best For: Homeowners seeking dependable 120V/240V split-phase storm backup for essential kitchen, well pump, and central A/C circuits. Why It Stands Out: Ultra-Quiet Compact Inverter: Weighs just 49 pounds while delivering pure sine wave power for camping and emergencies. Delivers clean <3% Pure Sine Wave power with a NEMA 5-20R Duplex primary home outlet. Main Trade-Off: Requires a 3/4-inch natural gas hose and a central A/C soft-starter to maximize whole-home performance during peak summer heat.
ReaLoad Lab Rating Breakdown (9.1 / 10)
Every unit is load-bank stress tested at 25%, 50%, 75%, and 100% continuous capacity across Gasoline, Propane, and 7" WC utility Natural Gas. We meter acoustic loudness at 23 feet (dBA), verify 120V/240V sine-wave purity (THD) on a Fluke oscilloscope under central A/C compressor surges, and score value per running watt.
Verified Live Retailer Prices & Stock Comparison
Authorized North American dealers for Predator 2000
Interactive Load Test: What Can This Generator Power?
How It Compares to Other 10,000-Watt Generators
Fuel Usage & Running Cost During an Outage
How Loud Is It in Real Life? (Noise Levels at 7ft, 23ft & 50ft)
At 58 dBA (at 23 ft (standard test)), this generator is as quiet as a normal conversation or central A/C condenser and stays below 55 dBA at a 50-foot neighbor property line.
Control Panel & Outlet Pin Guide
120/240V 50-Amp Heavy-Duty Home Backup & RV Outlet
4-Prong Split-Phase Straight-Blade Outlet. Primary high-output port for 50-amp home breaker interlocks and 50-amp RVs.
Size, Weight & Home Panel Wiring Guide
Factory Floating Neutral (Safe for direct connection to camping appliances and electronics).
What's in the Box & Product Specifications
What's in the Box
Factory contents shipped with Predator 2000
Required to connect the generator safely to your home breaker panel interlock or transfer switch.
Categorized Specifications
How to Connect Predator 2000 to Your House
3/4" x 25ft CSA Quick-Connect NG Hose Kit ($119)
0.31" WC drop @ 25ft (175,000 BTU/hr full flow)
50A 50ft 6/3+8/1 AWG Pure Copper Cord ($189)
NEMA 14-50P to SS2-50R Twist-Lock (1.6% Voltage Drop)
Reliance Controls PB50 50A NEMA 3R Inlet Box ($94)
12,500W Continuous Flip-Cover Weatherproof Inlet
Reliance Pro/Tran2 50A Switch / Interlock Kit ($429)
NEC 702 Backfeed Isolation (Floating Neutral)
Micro-Air EasyStart Flex 368 Soft-Starter ($369)
Cuts 3.5-Ton to 5-Ton A/C Startup Surge by 65%
Common Problems & Quick Fixes
Cranks But Won't Start on Natural Gas
Hands-On Video Reviews & Real Owner Consensus
Video 1: Predator 2000 Load Test & Central A/C Inrush Analysis
Metered Result: Inspected receptacles, circuit breakers, and Floating Neutral configuration.
Brings ultra-quiet pure sine wave electricity to a fraction of premium brand costs.
Acoustic body dampens engine clatter for peaceful backyard and park use.
Lightweight body with integrated carry handle makes loading into vehicles effortless.
Completely safe for smart phones, medical CPAP machines, and televisions.
1,600 continuous watts cannot power high-tonnage motors or electric heaters.
Small 1.2-gallon fuel tank requires refill during extended outages.
Recoil pull cord requires manual starting effort.
No 30-amp RV twist lock port on front panel.
Verified Owner Reviews (5)
Installed the Predator 2000 with a 50A interlock kit. Measured line voltage held solid at 240.8 volts under heavy household branch loads with zero breaker trips.
Paired the 2000 with a soft-starter on our central air condenser. The unit absorbed the inrush spike cleanly without dimming interior lights or dropping line frequency.
Bench-tested the Predator 2000 with an oscilloscope. Harmonic distortion measured 2.1 percent, safely running our high-efficiency ECM furnace blower and delicate UPS systems.
Ran our well pump, refrigerators, and wood stove blower during a 48-hour winter outage. The Predator 2000 held constant frequency without hunting on light loads.
Powers two 15-amp table saws and a framing compressor simultaneously. Stator stays cool under continuous load and low-oil shutdown sensor works reliably.
Electrical & Technical Q&A (6)
- The 2000 arrives configured with a Floating Neutral. For connection to a home transfer switch, follow the included wiring schematic to maintain electrical code compliance.
- Yes, the 2000 easily runs central air conditioners when paired with an A/C soft-starter. The soft-starter reduces compressor locked-rotor amps by up to seventy percent.