Product imagery is shown for reference; check exact connector configuration and included fittings before installation.
Westinghouse WATS200 200A Whole-Home Automatic Transfer Switch (NEMA 3R, UL 1008)
Manual interlocks force you outside in freezing rain to start a portable generator and flip breakers by hand. The Westinghouse WATS200 is a 200A service entrance rated automatic transfer switch (ETL listed to UL 1008, 22kA SCCR) built exclusively for 2017 and newer Smart Switch Ready Westinghouse generators. It detects grid loss, auto-starts the engine over the included 25-foot ST cable, maintains the starter battery, and sheds up to four A/C loads.
Overview & Key Impact
Engineered for residential backup power systems requiring 200a service entrance rated | nema 3r aluminum | built-in 4-load a/c management | ul 1008, measurable improvement from 300 Seconds (manual outage startup & switchover) to 30 Seconds (automated ats start & transfer), and zero thermal voltage drop across UL-listed transfer panels.
Step-by-Step Installation Overview
Pull Permit & Hire Licensed Electrician
Because the WATS200 is service entrance rated at 200A (22kA SCCR), utility meter disconnection and local electrical inspection are required.
Mount NEMA 3R Aluminum Enclosure
Install the 29.5-lb weatherproof cabinet indoors or outdoors between the utility meter base and your main residential distribution panel.
Wire Separate 50A Inlet & A/C Shedding
Connect a separate 50A exterior inlet box to the generator lugs and wire low-voltage thermostat lines for up to four HVAC circuits.
Connect 25-Foot ST Control Cable
Plug the included 25-foot ST control harness into your Smart Switch Ready Westinghouse generator and test automatic utility-loss transfer.
Electrical & Mechanical Specifications
| Manufacturer / Brand | Westinghouse |
|---|---|
| Model / Part Number | WATS200 (200A Service Entrance Rated Automatic Transfer Switch) |
| Equipment Category | Transfer Switches & Interlocks |
| Primary Engineering Rating | 200A Service Entrance Rated | NEMA 3R Aluminum | Built-In 4-Load A/C Management | UL 1008 |
| Baseline vs. Upgraded Metric | 300 Seconds baseline -> 30 Seconds after install |
| Safety & Code Compliance | NEC Article 702.5 · UL 1008 Manual Backfeed Isolation Switch |
| Compatibility Coverage | Engineered Fit across 9 compatible portable & standby generators |
| Installation Workflow | 4-Step Home Hookup Procedure |
Compatible Portable & Standby Generators (9)
Compatible Portable & Standby Generators (9)
Connects through the 25-foot ST control cable to convert the iGen11000DFc into an automated standby backup source.
Links to the Smart Switch Ready outlet on the iGen12000DFc to automate whole-home transfer and manage up to four A/C circuits.
Plugs directly into the Smart Switch Ready port on the iGen12000TFc for automatic outage start, stop, and 12V battery float charging.
Communicates over the included 25-foot ST control cable to auto-start the WGen10500TFc during grid failures.
Turns the WGen11500TFc tri-fuel generator into an automated whole-home backup system with 200A service entrance protection.
Supports hands-free utility-loss startup and generator battery maintenance through the WGen12000DF Smart Switch port.
Automates outage startup and transfer on the WGen14500TFc while shedding up to four HVAC loads automatically.
Pairs with the 20,000W WGen20000c Smart Switch port for automated 200A whole-house service entrance transfer.
Connects via the ST control port on the WGen9500TFc for automatic transfer and built-in A/C load management.
Related Guides & Hookup Walkthroughs
Sizing, NEC transfer wiring, and fuel setup checklists paired for the Westinghouse WATS200 200A Whole-Home Automatic Transfer Switch (NEMA 3R, UL 1008).

Westinghouse WATS200 Automatic Transfer Switch Guide: 200A Smart Switch Setup
Engineering guide to the Westinghouse WATS200 200A service entrance automatic transfer switch: compatible tri-fuel generators, 4-load A/C management, and required parts.

Best Manual Transfer Switches for Portable Generators (6-Circuit to 10-Circuit)
Compare 30A and 50A manual transfer switches including Reliance Pro/Tran2 and single-circuit furnace switches for code-compliant NEC Article 702 backup.

50-Amp Generator Inlet Box & Interlock Wiring: NEC 702
Step-by-step wiring guide for installing a 50-amp CS6365 power inlet box and breaker interlock kit. Size 6 AWG copper conductors for safe backup power.
Field Installer & Owner Feedback (3)
Our electrician mounted the aluminum NEMA 3R cabinet right beside our meter base. Built-in A/C load management prevents our two condensers from colliding during transfer.
Clean internal lug spacing and solid aluminum weatherproof housing. Built-in generator battery charging keeps the portable unit ready between seasonal storms.
We wanted standby automation without buying a permanent air-cooled unit. Hooked to our iGen12000TFc under a vented enclosure, it kicked on cleanly during an overnight outage.
Technical Q&A (3)
Answer: No. The WATS200 uses Westinghouse proprietary ST control signaling and only works with 2017 and newer Westinghouse generators equipped with a Smart Switch Ready control outlet.
Answer: No. The carton includes the 200A ATS enclosure, 25-foot ST control cable, fault current label, and manual. You must supply a matching 50A 6-AWG power cord and exterior inlet box separately.
Answer: Yes. The WATS200 ships in an aluminum NEMA 3R indoor/outdoor enclosure, is ETL listed to UL 1008, and is service entrance rated for 200A single-phase utility installations.