Skip to main content
Affiliate Disclosure: As an Amazon Associate I earn from qualifying purchases. ReaLoad may earn commissions from partner links at no extra cost to you. Editorial & Affiliate Policy ->
Hookup & Transfer 8 min read : UL 1008 Automatic Transfer Switches & NEC Article 702 Service Entrance

Westinghouse WATS200 Automatic Transfer Switch Guide: 200A Smart Switch Setup

ReaLoad Engineering Desk : Published 2026-11-26 :
Aluminum NEMA 3R 200-amp automatic transfer switch mounted neatly next to a residential exterior utility meter and 50-amp generator inlet
Quick Summary

The Westinghouse WATS200 converts 2017 and newer Smart Switch Ready Westinghouse generators into hands-free whole-home standby systems using a 200A service entrance rated NEMA 3R cabinet and built-in 4-load A/C management. Budget separately for a 50A exterior inlet box, 6-AWG cord, and licensed electrician installation.

Share:

01 How Does the Westinghouse WATS200 Automate a Portable Tri-Fuel Generator?

Most homeowners assume automatic outage switchover requires buying a permanent 18kW to 26kW air-cooled standby generator. The Westinghouse WATS200 bridges that gap for Smart Switch Ready portable tri-fuels.

Wired ahead of your 200A main breaker panel, the WATS200 monitors utility voltage continuously, sends an automatic start signal over its included 25-foot ST control cable during blackouts, transfers power in roughly 30 seconds, and float-charges the generator starter battery.

Compatible Westinghouse Model Natural Gas Run / Peak THD Rating Best WATS200 Pairing
WGen10500TFc (500cc)8,500W / 10,000W<=23% AVRHigh-value 200A automated backup
WGen11500TFc (550cc)9,500W / 12,000W<5% Low-THDBest overall automated tri-fuel
iGen12000TFc (457cc)7,200W / 9,800W<3% InverterQuietest 64 dBA automated setup
WGen14500TFc (713cc)11,600W / 14,500W<5% Low-THDMaximum whole-home HVAC load
Engineering Benchmark Data Scroll right to inspect
Interactive Sizing Calculator
Determine conductor resistance and voltage drop limits for 30A and 50A cords.
Calculate Generator Cord Wire Gauge & Drop
Key Takeaway: WATS200 works strictly with 2017+ Westinghouse Smart Switch Ready models and never with third-party generator brands.

02 Built-In 4-Load A/C Management & Required Missing Parts

Because a 50A portable generator feeds at most 12,000W into a 200A house panel, the WATS200 integrates smart load management for up to four HVAC circuits so two condensers never start simultaneously.

Two critical hardware parts are NOT included in the WATS200 box: you must purchase a weatherproof 50A Reliance PBN50 Inlet Box and a 50A 6-AWG Generator Cord.

  • Pair with the WGen10500TFc or WGen11500TFc connected to utility natural gas for unattended multi-day runs.
  • Confirm 6-AWG copper voltage drop across your cord run using our Cord Gauge & Voltage Drop Calculator.
  • Keep the portable generator inside a vented weather enclosure if you expect unattended starts during storms.
Key Takeaway: Add a 50A inlet box, 6-AWG cord, and weather shelter to complete a safe unattended WATS200 system.

03 Service Entrance Installation & Permit Checklist

The WATS200 carries an ETL listing to UL 1008, a 22,000A short-circuit current rating (SCCR), and a NEMA 3R aluminum enclosure approved for indoor or outdoor service entrance installation between the utility meter and main load center.

Because installation involves pulling the utility meter and re-landing 200A service feeders, hire a licensed electrical contractor to handle local permits and neutral-ground bonding compliance.

Key Takeaway: Service-entrance UL 1008 compliance simplifies passing local utility and municipal electrical inspections.
Key Field Takeaways
  • Westinghouse WATS200 is a 200A service-entrance NEMA 3R automatic switch with 4-load HVAC shedding.
  • Includes a 25-foot ST control cable that auto-starts compatible Westinghouse generators and float-charges their 12V battery.
  • Requires buying a separate 50A exterior inlet box, 6-AWG power cord, and licensed electrician installation.

Frequently Asked Questions

Q: Can I connect a DuroMax, Champion, or Predator generator to the Westinghouse WATS200?

No. The WATS200 uses Westinghouse's proprietary ST control connector and only automates 2017 and newer Westinghouse Smart Switch Ready models.

Q: Does the WATS200 replace my existing 200A main breaker panel?

No. Your electrician installs the WATS200 inline between the utility meter base and your existing 200A main breaker panel, turning the main panel into a downstream subpanel.

Q: Do I still need a soft-starter on a 4-ton or 5-ton central A/C with the WATS200?

Yes. While the WATS200 staggers multiple A/C units, adding a Hyper SureStart SS1B16-32SN or Micro-Air EasyStart Flex cuts individual compressor surge up to 70% so your 8.5kW to 9.5kW NG generator starts it cleanly.

Head-to-Head Generator Comparisons
Certified Regional Electrician & Plumbing Hubs